[product name] disposable laryngoscope
[specification and model] 0, 1, 2, 3, 4#
[name of registrant] Henan Jianqi medical device Co., Ltd
[residence] dingluan Industrial Zone, Changyuan County
[Tel.] 0373-8690789
[after sales service unit] Henan Jianqi medical equipment sales Co., Ltd
[name of manufacturer] Henan Jianqi Medical Equipment Co., Ltd
[residence] dingluan Industrial Zone, Changyuan County
[production address] dingluan Industrial Zone, Changyuan County
[contact information] 0373-8690789
[production license] ysyjx production license No. 20080036
[Registration Certificate No.] yxzz 20162660346
[technical requirements No.] yxzz 20162660346
[structure and composition] this product is composed of lens body and optical fiber.
[product performance] 1. The surface of laryngoscope should be clean, smooth, free of impurities, burr and injection flow. 2. The brightness loss of the light source after switching on shall not be higher than 10% compared with that before switching on. 3. The plane of the fitting part with the mirror handle should be in the same horizontal plane with the cross section of the optical fiber, and the cross section of the light guiding optical fiber is facing the light source of the mirror handle, and the connection should be firm. 4. The residual content of ethylene oxide should not be more than 10 μ g / g. 5. The product should be sterile.
[scope of application] it can be used to assist intubation in clinical laryngeal examination, first aid and anesthesia operation.
[contraindications] no contraindications.
[precautions] 1. This product is disposable and its package is damaged. It is forbidden to use it and destroy it after use.
2. The production batch number is shown in the seal or certificate, and the sterilization date is shown in the outer packing box.
3. The product was sterilized by ethylene oxide.
[usage] 1. Select the specifications and models of the patients, and open the package after confirming that the outer package is in good condition.
2. First connect the lens and the handle to make the lens match with the metal parts of the handle, and then the lens lighting is turned on.
3. Insert the lens into the mouth and throat, stir up the epiglottis to expose the glottis, and guide the medical staff to accurately intubate or check the larynx.
4. After the end of use, the product should be treated as medical waste to avoid pollution.
[storage method] 1. The product should be loaded and transported in covered carriage and cabin, and kept clean. It should not be under heavy pressure, direct sunlight, rain or snow.
2. Handle with care to avoid violent collision;
3. The product should be stored away from the fire source, the relative humidity is not more than 80%, no corrosive gas and well ventilated and clean environment.